In the premium version, the MOTUS®C14 is equipped with a display, which enables the programming of all functions and data retrieval. The programming can be done via the integrated USB interface of ServiceTool.
The communication interface enables connection to intelligent sensors and actuators in an automation system or bus systems through a gateway.
Motus®C14 Connect Plus
In the premium version, the MOTUS®C14 is equipped with a display, which enables the programming of all functions and data retrieval of the MOTUS®C14. The programming can be done via the integrated USB interface of ServiceTool.
The communication interface enables connection to intelligent sensors and actuators in an automation system or bus systems through a gateway.
Motus®C14 Connect Plus
Motus®C14 Connect Plus
The ServiceTool of Wöhner provides the following functionalities:
Motus®C14 Connect Plus
All connections of the MOTUS®C14 are pluggable and thus enable quick wiring of the devices.
The control plug is located on the upper section of the MOTUS®C14. It can be used either for conventional or
IO-Link wiring.
With IO-Link wiring, the connection is made via 3 wires: supply voltage 24 V DC (+), GND and C/Q data.
The lower section of the MOTUS®C14 is used to wire the T1, T2 and T3 load plug. The cable is clamped to the plug using a screw clamp connection.
The USB interface is also located on this side. This interface enables via the ServiceTool the parameterisation and the data retrieval of the device.
The MOTUS®C14 uses CrossLink®Technology and can be plugged directly onto the CrossBoard®. With an adapter, the device can be mounted on the systems 30Compact and 60Classic or in the system Panel on the DIN mounting rail. With all types, the contacts of the CrossLink® adapter or the CrossBoard® remain touch-safe while removing the electronic unit.
The mechanical and electrical connection (up to 500 V) is done without using tools when the device is snapped onto the CrossLink® interface during installation. The integrated contact protection prevents the contacts from being damaged during transport, mounting and dismounting.
Motus®C14 Connect Plus
The MOTUS®C14 switches faster than circuit breakers and faster than fuses in case of a fault.
rated operating voltage | 130 - 500 V (IEC) 130 - 480 V (UL) |
---|---|
rated operating current for motors |
2.6 A / 1.1 kW 6.6 A / 3.0 kW 12.0 A / 5.5 kW (on request) |
rated operating current for resistive loads |
2.6 A / 1,8 kW 6.6 A / 4.5 kW 12.0 A / 8.3 kW (on request) |
short-circuit resistance | 100 kA, coordination type 2 |
control voltage | 24 V DC |
electrical switching cycles | > 30 million |
connection plugs | control circuit: 0.2 - 1.5 mm² (solid, flexible) / AWG 24 - 16 load circuit: 0.2 - 2.5 mm² (solid, flexible) / AWG 24 - 14 |
dimensions (w x h x d) |
CrossBoard®: 22.5 x 160 x 130 mm 30Compact: 22.5 x 160 x 130 mm + 14 mm adapter 60Classic: 22.5 x 200 x 130 mm + 14 mm adapter |
approval IEC | IEC / EN 60947-4-2 / -3 |
approvel UL | UL listed (C-UL-US) |
article overview | MOTUS®C14 Connect Plus - CrossBoard® 36258: electronic unit 0.1 - 2.6 A / switch for resistive loads 0.1 - 2.6 A 36262: electronic unit 0.1 - 6.6 A / switch for resistive loads 0.1 - 6.6 A 36266: electronic unit 0.1 - 12.0 A / switch for resistive loads 0.1 - 12.0 A* MOTUS®C14 Connect Plus - 30Compact 36256: reversing starter 0.1 - 2.6 A / switch for resistive loads 0.1 - 2.6 A 36260: reversing starter 0.1 - 6.6 A / switch for resistive loads 0.1 - 6.6 A 36264: reversing starter 0.1 - 12.0 A / switch for resistive loads 0.1 - 12.0 A* MOTUS®C14 Connect Plus - 60Classic 36257: reversing starter 0.1 - 2.6 A / switch for resistive loads 0.1 - 2.6 A 36261: reversing starter 0.1 - 6.6 A / switch for resistive loads 0.1 - 6.6 A 36265: reversing starter 0.1 - 12.0 A / switch for resistive loads 0.1 - 12.0 A* MOTUS®C14 Connect Plus - Panel 36255: reversing starter 0.1 - 2.6 A / switch for resistive loads 0.1 - 2.6 A 36259: reversing starter 0.1 - 6.6 A / switch for resistive loads 0.1 - 6.6 A 36263: reversing starter 0.1 - 12.0 A / switch for resistive loads 0.1 - 12.0 A* * article on request |
MOTUS®C14 CONNECT PLUS
Bar chart shows the maximum inrush currents in cold state for a single start
MOTUS®C14 CONNECT PLUS
Permissible repeatable overcurrent factor to rated operating current (AC-53a)